TUV TEST RESULTS
Staphylococcus aureus ATCC 33592
CONTACT TIME (HOUR, MINUTE) | CONCENTRATION OF ORGANISM (CFU/ml) | APPARENT OVERALL REDUCTION BY PERCENTAGE (%) | APPARENT OVERALL LOG REDUCTION NUMBER |
---|---|---|---|
0 | 21000 | 0 | 0.00 |
5 | 14000 | 33.33 | 0.18 |
30 | 11000 | 47.62 | 0.28 |
60 | 9800 | 53.33 | 0.33 |
6 hr | 60 | 99.71 | 2.54 |
CONTACT TIME (HOUR, MINUTE) | 0 |
5 |
30 |
60 |
6 hr |
CONCENTRATION OF ORGANISM (CFU/ml) | 21000 |
14000 |
11000 |
9800 |
60 |
APPARENT OVERALL REDUCTION BY PERCENTAGE (%) | 0 |
33.33 |
47.62 |
53.33 |
99.71 |
APPARENT OVERALL LOG REDUCTION NUMBER | 0.00 |
0.18 |
0.28 |
0.33 |
2.54 |
Lab Test Verified
third party report
PARAMETER | CONTROL (CFU/M3) |
EXPOSED TIME | RESULT (CFU/M3) |
REDUCTION (%) |
---|---|---|---|---|
Total Baterial Count | 275 | at “30 minute” | 205 | 25.45% |
at “1 hour” | 115 | 58.18% | ||
at “3 hours” | 65 | 76.36% | ||
at “6 hours” | 20 | 92.73% | ||
at “24 hours” | 15 | 94.55% | ||
Total Fungal Count | 460 | at “30 minute” | 260 | 43.48% |
at “1 hour” | 120 | 73.91% | ||
at “3 hours” | 55 | 88.04% | ||
at “6 hours” | 55 | 88.04% | ||
at “24 hours” | 50 | 89.13% |
PARAMETER | Total Baterial Count | Total Fungal Count |
---|---|---|
CONTROL (CFU/M3) |
275 | 460 |
EXPOSED TIME |
at “30 minute” | at “30 minute” |
at “1 hour” | at “1 hour” | |
at “3 hours” | at “3 hours” | |
at “6 hours” | at “6 hours” | |
at “24 hours” | at “24 hours” | |
RESULT (CFU/M3) |
205 | 260 |
115 | 120 | |
65 | 55 | |
20 | 55 | |
15 | 50 | |
REDUCTION (%) |
25.45% | 43.48% |
58.18% | 73.91% | |
76.36% | 88.04% | |
92.73% | 88.04% | |
94.55% | 89.13% |
UGENE LAB TEST RESULTS
Antibacterial evaluation for EV Sun LED light coated with Germicidal Resonance coating film
S. aureus ATCC 25923
CONTACT TIME (HOUR, MINUTE) |
CONCENTRATION OF CONTAMINATED BACTERIA (CFU/ml) |
CONCENTRATION OF BACTERIA IN CONTACT TIME (CFU/ml) |
CONCENTRATION OF BACTERIA ON BLANK (CFU/ml) |
REDUCTION OF BACTERIA IN PERCENTAGE (%) |
BACTERIA REDUCTION (lg) |
---|---|---|---|---|---|
0 | 21000 | 21000 | 0 | 0 | 0 |
5 | 21000 | 14000 | 0 | 33.33 | 0.18 |
30 | 21000 | 11000 | 0 | 47.62 | 0.28 |
60 | 21000 | 9800 | 0 | 53.33 | 0.33 |
6 hr | 21000 | 60 | 0 | 99.71 | 2.54 |
24 hr | 21000 | 13 | 0 | 99.94 | 3.21 |
CONTACT TIME (HOUR, MINUTE) |
0 |
5 |
30 |
60 |
6 hr |
2 4hr |
CONCENTRATION OF CONTAMINATED BACTERIA (CFU/ml) |
21000 |
21000 |
21000 |
21000 |
21000 |
21000 |
CONCENTRATION OF BACTERIA IN CONTACT TIME (CFU/ml) |
21000 |
14000 |
11000 |
9800 |
60 |
13 |
CONCENTRATION OF BACTERIA ON BLANK (CFU/ml) |
0 |
0 |
0 |
0 |
0 |
0 |
REDUCTION OF BACTERIA IN PERCENTAGE (%) |
0 |
33.33 |
47.62 |
53.33 |
99.71 |
99.94 |
BACTERIA REDUCTION (lg) |
0 |
0.18 |
0.28 |
0.33 |
2.54 |
3.21 |
E. coli ATCC 25922
CONTACT TIME (HOUR, MINUTE) |
CONCENTRATION OF CONTAMINATED BACTERIA (CFU/ml) |
CONCENTRATION OF BACTERIA IN CONTACT TIME (CFU/ml) |
CONCENTRATION OF BACTERIA ON BLANK (CFU/ml) |
REDUCTION OF BACTERIA IN PERCENTAGE (%) |
BACTERIA REDUCTION (lg) |
---|---|---|---|---|---|
0 | 19000 | 19000 | 0 | 0 | 0 |
5 | 19000 | 17000 | 0 | 10.53 | 0.05 |
30 | 19000 | 16000 | 0 | 15.79 | 0.07 |
60 | 19000 | 15000 | 0 | 21.05 | 0.10 |
6 hr | 19000 | 63 | 0 | 99.67 | 2.48 |
24 hr | 19000 | 3 | 0 | 99.98 | 3.80 |
CONTACT TIME (HOUR, MINUTE) |
0 |
5 |
30 |
60 |
6 hr |
2 4hr |
CONCENTRATION OF CONTAMINATED BACTERIA (CFU/ml) |
19000 |
19000 |
19000 |
19000 |
19000 |
19000 |
CONCENTRATION OF BACTERIA IN CONTACT TIME (CFU/ml) |
19000 |
17000 |
16000 |
15000 |
63 |
3 |
CONCENTRATION OF BACTERIA ON BLANK (CFU/ml) |
0 |
0 |
0 |
0 |
0 |
0 |
REDUCTION OF BACTERIA IN PERCENTAGE (%) |
0 |
10.52 |
15.79 |
21.05 |
99.67 |
99.98 |
BACTERIA REDUCTION (lg) |
0 |
0.05 |
0.07 |
0.10 |
2.48 |
3.80 |
TUV LAB TEST RESULTS
Airborne Test in Hospital
sample description |
sample No. | sc.24050088 | sc.24050090 | sc.24050091 | sc.24050092 | sc.24050093 |
times | before | 1 HouR | 3 HouR | 6 HouR | 24 HouR | |
Results | Total Plate Count |
245 | 25 | 20 | 38 | 34 |
![]() |
![]() |
![]() |
![]() |
![]() |
||
Yeast and Mold | 264 | 58 | 33 | 48 | 26 | |
![]() |
![]() |
![]() |
![]() |
![]() |
The Reduction of Bacterial and Fungal Count for the Installation of EV Sun Germicidal Lamp
Conclusion: Based on such measurement, it can be seen that the measured values of fungi and bacteria in the air showed
a noticeable decrease after switching on the light according to the proportion measured during the specified period.
ASTAR LAB TEST RESULTS
test organism |
initial concentration (cfu/ml) |
exposed time |
sample | Result (cfu/ml) |
Reduction (%) |
---|---|---|---|---|---|
S.aureus ATCC 6538 |
6.9 x 105 | at “1 min” | Control - 24 Watts LED Light | 6.9 x 105 | N/A |
24 Watts - Resonance TL - E34C Series | 2.4 x 105 | 63.6% | |||
at “2 min” | Control - 24 Watts LED Light | 6.9 x 105 | N/A | ||
24 Watts - Resonance TL - E34C Series | 2.3 x 105 | 65.2% | |||
at “5 min” | Control - 24 Watts LED Light | 6.9 x 105 | N/A | ||
24 Watts - Resonance TL - E34C Series | 2.2 x 105 | 66.6% | |||
at “10 min” | Control - 24 Watts LED Light | 6.9 x 105 | N/A | ||
24 Watts - Resonance TL - E34C Series | 2.0 x 105 | 69.7% | |||
at “60 min” | Control - 24 Watts LED Light | 6.9 x 105 | N/A | ||
24 Watts - Resonance TL - E34C Series | 1.7 x 105 | 74.2% |
The figure above shows the reduction of Staphylococcus aureus on the sample for 1 minute, 2 minutes, 5 minutes, 10 minutes and 60 minutes exposure time.
Conclusion: According to the standard test method APHA 9020B (2017), 99% of bacteria should be killed in the exposed plate. Based on the experimental test Staphylococcus aureus has successfully achieved >60% bacterial reduction under sample exposure using a bacterial suspension test at 1-minute exposure time. It shall be noted that the LED lighting samples are coated for 1.5 years and retested for efficacy.
Flicker-free Technology for the Ultimate Comfort
The existing technologies in LED lighting sometimes cause flicker at frequencies that may have adverse health effects. Although, not always obvious to the human eye, this flicker has the potential to exert harmful effects on health such as eye strain, fatigue, headache, migraine, blurred vision as well as photo epilepsy in sensitive individuals.
*Source: Journal of Clinical and Diagnostic Research. 2019 May, Vol-13(5): NE01-NE05
Fret not, as our EVLN technology produces lights that are 100% flicker-free, ensuring a lasting comfortable and productive environment for anyone that requires long hours under the light.
Harnessing the Pinnacle of Technology with the Finest Imported LED Chips
By tapping into the expertise of top-tier manufacturers producing high-quality LED chips, EV Lighting excels in creating revolutionary LED lights that set a new standard for the entire lighting industry. Whether it’s achieving exponential brightness, enhanced durability, improved energy efficiency, or a heightened level of eco-friendliness, our commitment to utilizing the best-quality imported LED chips underscores our dedication to pushing the boundaries of illumination.
Resilient Aluminium Alloy Casing with RoHS-compliant Coating
Blending pure aluminium with robust metals to forge a resilient aluminium alloy casing, coated with RoHS-compliant protection, results in an extremely durable and eco-friendly LED light casing. This fortified structure not only withstands corrosion but also boasts exceptional heat dissipation capabilities, preventing the formation of microcracks in LED lights. The prevention of microcracks is crucial as they are implicated in the release of harmful VOCs (volatile organic compounds) into the environment, posing risks to both humans and the ecosystem.
The existing technologies in LED lighting sometimes cause flicker at frequencies that may have adverse health effects. Although, not always obvious to the human eye, this flicker has the potential to exert harmful effects on health such as eye strain, fatigue, headache, migraine, blurred vision as well as photo epilepsy in sensitive individuals.
*Source: Journal of Clinical and Diagnostic Research. 2019 May, Vol-13(5): NE01-NE05
Fret not, as our EVLN technology produces lights that are 100% flicker-free, ensuring a lasting comfortable and productive environment for anyone that requires long hours under the light.
By tapping into the expertise of top-tier manufacturers producing high-quality LED chips, EV Lighting excels in creating revolutionary LED lights that set a new standard for the entire lighting industry. Whether it’s achieving exponential brightness, enhanced durability, improved energy efficiency, or a heightened level of eco-friendliness, our commitment to utilizing the best-quality imported LED chips underscores our dedication to pushing the boundaries of illumination.
Blending pure aluminium with robust metals to forge a resilient aluminium alloy casing, coated with RoHS-compliant protection, results in an extremely durable and eco-friendly LED light casing. This fortified structure not only withstands corrosion but also boasts exceptional heat dissipation capabilities, preventing the formation of microcracks in LED lights. The prevention of microcracks is crucial as they are implicated in the release of harmful VOCs (volatile organic compounds) into the environment, posing risks to both humans and the ecosystem.
Excellent Quality Lighting Design that Revolutionise the Global Lighting Industry


PCB Power Board
Efficient AC to DC conversion. Eliminates flickering light that is bad for eyes.
Aluminium Casting
Superior heat dissipation, channelling heat away from the light source.
Fixing Spring Clip
Ensures stable mounting for long-lasting reliability.
Lens Panel
Advanced lens technology enhances sterilisation effectiveness against airborne and surface pathogens.
LED Power Driver Casing
Stabilises and regulates power supply for enhanced durability and reliability.
Wire Protection Holder
Safeguards wiring for stable electrical connections.
LED Module
Utilises top thermal paste for maximum heat dissipation and prolonged lifespan.
Polycarbonate Cover